LIGHTERS or LIGHTER REFILLS containing flammable gas
ADR 2025 · Class 2 · carriage of dangerous goods by road
- Class
- 2
- Classif.
- 6F
- Hazard labels
- 2.1
- Transport cat.
- 2 (D)
- Class
- 2
- Classification code
- 6F
- Hazard labels
- 2.1

- Limited quantities
- 0
- Excepted quantities
- E0
- Packing instructions
- P002
- Mixed packing
- MP9
- Exemption limit
- 333 kg/L
Special provisions
SP 201
Lighters and lighter refills shall comply with the provisions of the country in which they were filled. They shall be provided with protection against inadvertent discharge. The liquid portion of the gas shall not exceed 85 % of the capacity of the receptacle at 15 °C. The receptacles, including the closures, shall be capable of withstanding an internal pressure of twice the pressure of the liquefied petroleum gas at 55 °C. The valve mechanisms and ignition devices shall be securely sealed, taped or otherwise fastened or designed to prevent operation or leakage of the contents during carriage. Lighters shall not contain more than 10 g of liquefied petroleum gas. Lighter refills shall not contain more than 65 g of liquefied petroleum gas. NOTE: For waste lighters collected separately see Chapter 3.3, special provision 654.
SP 654
Waste lighters collected separately and consigned in accordance with 5.4.1.1.3.1 may be carried under this entry for the purposes of disposal. They need not be protected against inadvertent discharge provided that measures are taken to prevent the dangerous buildup of pressure and dangerous atmospheres. Waste lighters, other than those leaking or severely deformed, shall be packed in accordance with packing instruction P003. In addition the following provisions shall apply: -Only rigid packagings of a maximum capacity of 60 litres shall be used; -The packagings shall be filled with water or any other appropriate protection material to avoid any ignition; -Under normal conditions of carriage all ignition devices of the lighters shall fully be covered by the protection material; -The packagings shall be adequately vented to prevent the creation of flammable atmosphere and the buildup of pressure; -The packages shall only be carried in ventilated or open vehicles or containers. Leaking or severely deformed lighters shall be carried in salvage packagings, provided appropriate measures are taken to ensure there is no dangerous buildup of pressure. NOTE: Special provision 201 and special packing provisions PP84 and RR5 of packing instruction P002 in 4.1.4.1 do not apply to waste lighters.
SP 658
UN No. 1057 LIGHTERS complying with standard EN ISO 9994:2019 "Lighters – Safety Specification" and UN No. 1057 LIGHTER REFILLS, may be carried subject only to the provisions of 3.4.1 (a) to (h), 3.4.2 (except for the total gross mass of 30 kg), 3.4.3 (except for the total gross mass of 20 kg), 3.4.11 and 3.4.12, provided the following conditions are met: (a) The total gross mass of each package is not more than 10 kg; (b) Not more than 100 kg gross mass of such packages is carried in a vehicle or large container; and (c) Each outer packaging is clearly and durably marked with "UN 1057 LIGHTERS" or "UN 1057 LIGHTER REFILLS", as appropriate.